Description
General Information
Product Type: Gas Continuous Flow
Suitable for:
• Commercial and domestic external applications
• Applications requiring higher hot water temperatures, can be set up to 95 °C
• Mains and low pressure systems
Hard or acidic water will need to be treated in order to use this product.
Gas type
Available for Natural Gas or LPG. Specify gas type at time of purchase.
Colour: Silver
Input: 250 MJ/h or 69 kW
Output: 55.2 kW
Efficiency: 80%
Energy Star Rating 5.3stars
Capacity Hot water capacity: 2.4 to 37 litres per minute
Nominal water capacity: 32 litres per minute at a 25 °C rise (1920 L/h)
Connections Hot water oulet: R¾ (20 mm)
Cold water inlet: R¾ (20 mm)
Gas supply: R¾ (20 mm)
Exhaust System Forced flue
Ignition System Direct electronic ignition
Injector Size (mm) NG: 1.00, 1.65 LPG: 0.75, 1.15
Line Pressure (min.) NG: 1.13 kPa, LPG:2.75 kPa
Line Pressure (max.)
3.5 kPa (maximum standing pressure under abnormal intermittent conditions is 5.0 kPa).
In the case of commercial metering (i.e. 35-37 kPa coming in), there may be a requirement to regulate the incoming line pressure down.
Power Consumption Normal: 72 W, Standby: 2 W, Automatic Frost Protection: 116 W
Pressure Relief Valve opens at 2060 kPa, valve closes at 1470 kPa
Noise Level 49 dB(A)
Safety Devices Flame failure, boil-dry protection, overheat protection (OHS), fusible link, pressure relief valve, combustion fan rpm check
Water Supply Nominal operating pressure: 200-1000 kPa
Minimum water flow: 2.4 litres per minute
Weight 29 kg
Reviews